Document Type : Original Research Article
Authors
1 Department of Biophysics, College of Science, University of Mosul, Mosul, Iraq
2 Biology Department, College of Science, Mustansiriyah University, Baghdad, Iraq
Abstract
Keywords
INTRODUCTION
VP-16 is a semi-synthetic glycoside derivative of podophyllotoxin, and initially an extract of the mandrake plant [1]. VP-16 is active against several tumors, including small lung cancers, testicular cancer [2], lymphoma, leukemia and Karposi’s sarcoma associated with AIDS. It is used in patients with advanced hematological malignancies as part of a bone marrow preparatory regimen[3, 4]. VP-16 undergoes an easy metabolism by numeral enzymatic processes, in vitro and in vivo to make reactive products. Our group was the first to discover that VP-16 is o-demethylated by horseradish peroxidase, cytochrome P450, and tyrosinase, to o-dihydroxy VP-16 (Fig. 1) and highly reactive o-quinone-VP-16 [5, 6].
One electron oxidation is required for formation of intermediates 4-hydroxyl group on VP16 to create a phenoxyl radical, which can be detected by EPR (Fig. 2) [7].
Methods used to assess VP-16 are HPLC [8-15], spectrofluorimetry [16], liquid chromatography–mass spectrometry [17, 18], fluorescence spectroscopy [19, 20], with chromatography of electrokinetic micellar [21]. Electrochemical techniques are sensitive in selective development methods for drug assessment. Voltammetric methods are sufficient for studying the redox properties of pharmaceutical active components [22]. Electronic properties suggest that MWCNTs have promoted the transfer of electron and the sensitivity has been improved in electrochemistry, therefore are used as working electrodes for drug analysis. Eosin-Yellowish (EOY) with IUPAC name of 2′,4′,5′,7′-tetrabromo fluorescein disodium salt , due to light absorption, high stability and versatility [23-25].
EXPERIMENTAL DETAILS
Instrumentation
Voltammetric measurements were recorded, using an electrochemical analyzer, Computrace ٧٩٧ VA (AG, Metrohm , CH-٩١٠١ Herisav, Switzerland).A cell with ٣ types of electrode, including a reference electrode with an Ag/AgCl with KCl saturated, a platinum wire counter electrode, and a Glassy C working electrode were used. The pH meter (digital HANNA, Portugal) was used to measure the pH [٢٦].
Materials
The pharmaceutical dose of VP-١٦ was provided by Koçak Farma Inc (Istanbul, Turkey). EOY was acquired from Fluka (BDH), and was in analytical grade. Britton Robinson and Tris-HCl buffers were applied by supporting electrolytes. The analytical grade (Fluka, BDH) chemicals and reagents used in this study were used with no further purification. Throughout the experimental work, double distillated water (DDW) was used.
of EOY-MWCNTs/GCE preparation
GCE polished with 0.3 and 0.05 μm alumina slurry consecutively and ultrasonically cleaned in nitric acid: acetone (1:1), for five minutes, reagent water type IV (ASTM D1193) [27-28]. On the pretreated GCE, 5 μl of MWCNT suspension was then applied and dry. Electropolymerisation of EOY was performed on the surface of bare GCE, using cyclic voltammetric technique, in solution harboring 1×10-3 M EOY in 0.2 M PBS at pH 6.0. The electropolymerisation was accomplished by the creation of a film, using (−1.5V to +2.0 V) potential at 50 mV×s−1 of scan rate for 14 cycles (Fig. 3).
RESULTS AND DISCUSSION
Electrochemistry of VP-16
The redox mechanism of VP-16 , the further application of bio-detection to 0.2 M PBS at pH 7.0 has been investigated, by CV sweeps between (+2.0 to −1.5 V)until stable voltammograms were acquired(Fig. 4).
Optimization of condition for VP-16
To optimize the conditions for measurements through CV technique, the voltammogram of 3.0 nM VP-16 in PBS at pH 7.0 [29], which was studied previously, used as supporting electrolyte. The table below shows optimal conditions for the parameters involved in the measurement of the VP-16 (Table 1) .
pH effect
Effect of pH on the 3.0×10-9 M VP-16 was assessed in the pH range of 4.0–9.0 in PBS by CV with a 100 mV×s−1 scan rate (Fig. 5-a). Increased pH shifted the oxidation potential to less positive values till pH 9.0, up until it became immeasurable. The correlation linear between oxidation potential and pH presented as follows:
(1)
Where Epa is expressed in mV, with r = 0.997.
Characterization of morphology of PEOY/GCE&MWCNTs/EOY/GCE by SEM
Fig.-6 (a-c) and Fig.-6 (d-f) show the morphology of PEOY/GCE and MWCNTs/PEOY/GCE by SEM respectively, using scanning electron microscope (SEM).
Electropolymeriztion of EOY on GCE
After 14 cycles(pH 6.0 PBS)( Fig. 7), the constant peak currents remain; thus, 14 no. of cycles are selected for the modification procedure. A consistent film is created on the GCE surface, indicating that the EOY has been placed on the GCE surface by electropolymeriztion technique.
Effect of pH
In the pH range of 4.0 to 8.0, the effect of pH on the current response of EOY was examined. The oxidation current slowly elevated with the increase of pH from 4 to 6. Nevertheless, when pH reached at 8, the peak current diminished. Thus, polymerization sensitivity of EOY at pH 6 was selected as the optimum pH for polymerization of EOY on the GC electrode surface. The relation between the peak current and pH was also shown in Fig 8-a, demonstrating an increase in oxidation current with increasing pH until pH 6.0, then a decrease was observed with increasing of pH value more than 6. For more accurate calibration curve, the correlation between EOY concentrations and oxidation current is presented in (Fig. 8-b).
Effect of cycle numbers and the layer thickness
Thickness can be overseen by altering the cycle number from 5 to 15 multiple cycles on GCE, corresponding to the electrocatalytic activity in regard to the oxidation of 3.0 ×10-8 M to 3×10-7 M VP-16 in 0.2 M PBS at pH 7.0.
14 cycles were selected as a representative typical example for the transformation of naked GCE. The (Fig. 9-b) shows the relation between cycle numbers and the peak current in the potential range of (−1.5 V to 2.0 V). As the positive potential is lower than the 2.0 V, no polymer film would be obtained, because of the lack of the monomer free radical EOY. As the cycle number increases more and reaches to the 15, the electrochemical activity of EOY film decreases(Fig. 9).
Effect of Scan Rate
The CVs of the response of the PEOY-MWCNTs/GC modified electrode were examined in PBS solution containing 5×10-8 M of VP-16 at pH=7(Fig. 10)., at various scan rates, and the potentials ranging from (-0.5V to 1.2 V). The results are illustrated in Fig 11-a. As it appeared, the peak currents have a linear relation with rate of scan between 100 and 400 mV×s−1.
Detection of VP-16 at poly (eosin yellow)/MWCNTs/GCE
Fig. 11 displays the PEOY-MWCNTs/GC electrode with injection of different concentrations of VP-16 at a working potential of 0.7 V, in comparison with a reference electrode. These data show that the modified electrode is stable and efficient. A linear relationship between response currents and VP-16 concentrations in the range of 3.0 ×10-8 M to 3×10-7 M has been found (Fig. 12). The linear equation for this linear range is an
(2)
With a R=0.996 correlation coefficient and a 0.434 μA/μM sensitivity.
Characterization of the electrochemical behavior of PEOY-MWCNTs/VP-16 /GCE
PEOY-MWCNTs/VP-16 was added to GC electrode, an oxidation peak for the analyte VP-16 /GCE was noted(Fig. 13); its oxidation current elevated and oxidation potential switched to negative values (curve c), which may be the consequence of electrocatalytic activity of PEOY /VP-16 /GCE. However, the anodic peak of VP-16 occurred at a greater negative potential in relation to PEOY-MWCNTs/VP-16 /GCE. Modification of PEOY-MWCNTs /GCE diminished the oxidation potential with an elevation of the peak current in comparison to PEOY-MWCNTs /GCE, which may be due to the synergic effect of both mediators, used in the PEOY-MWCNTs/VP-16 /GCE.
Analytical properties
Through the use of biosensors to check the viability of the biosensor through the use of five different biosensors in the presence of the sensors EOY-MWCNTs/GCE in five experiments forVP-16 estimation , the results gave value 8.36E-08(M) for LOD and gave 2.53E-07(M) for LOQ estimation with 5 experiments was obtained in (Table 2).
CONCLUSION
A new modified electrode was developed in this study using EOY electropolymerization to evaluate the VP-16 (anti-cancer drug); the PEOY-MWCNT / VP-16 / GCE sensor has good sensitivity and selectivity of EOY to VP-16. Low concentrations were estimated at (0.836 nM), following the polymer treatment of the electrode. By using MWCNTs, the electrode showed a high sensitivity as it improved the sensitivity of the electrode to measure the drug compared to the polymer alone, so it was very important to perform a practical application for measuring pharmaceutical models in patient samples
CONFLICT OF INTEREST
The authors of this have declared there is no conflict of interest.